Performance capabilities range from 150 to 1020 GPM depending on the size selected. Total Dynamic Heads (TDH) range from 20 feet to 80 feet, depending on the pump size and hydraulic motor selected. See below for GPM and TDH for each model listed.
Description. SRS Crisafulli S-Series, hydraulic powered pumps are portable, submersible pumps, available in three styles. The Severe Duty pumps feature dual mechanical seals and an oil-filled bearing frame which will isolate the motor from pumpage. All pumps have suction stands and threaded discharges (other discharge finishes available upon request).
|
|
|
Pump Size Inches
|
Flow - GPM
|
TDH - Feet
|
Solids Passing Capability Inches
|
SRSC Part Number
|
Motor Part Number
|
Est. weight - pounds
|
|
2
|
150
|
20
|
.50
|
HY022V-2505
|
HM2505
|
130
|
|
2.5
|
275
|
20
|
.50
|
HY252V-2505
|
HM2505
|
135
|
|
3
|
300
|
20
|
1.75
|
HY032V-2505
|
HM2505
|
145
|
|
3
|
330
|
25
|
1.75
|
HY032V-2507
|
HM2507
|
155
|
|
3
|
500
|
50
|
1.75
|
HY032V-2510
|
HM2510
|
155
|
|
4
|
550
|
20
|
2.50
|
HY042V-2510
|
HM2510
|
225
|
|
4
|
880
|
40
|
2.50
|
HY042V-2515
|
HM2515
|
225
|
|
4
|
1,020
|
60
|
2.50
|
HY042V-2520
|
HM2520
|
250
|
|
4
|
680
|
80
|
2.50
|
HY042V-2525
|
HM2525
|
255
|
|
Standard Options
|
| Hydraulic Slurry Gate (price is same for each size pump). “Slurry Gate” is opened to agitate and slurry the pond. Solids and liquids are drawn into the pump, blended and injected through the slurry gate into unmixed material. After a period of time, depending on material thickness, the entire pit will be slurried and the operator can close the slurry gate hydraulically from the bank. The pump will then pump the material out at high volume. No separate agitator or mixer pumps are needed. One SRS Crisafulli pump does it all. |
SRSC Part Number plus - SG |
| Stainless Steel Pump |
|
| Hydraulic Slurry Gate |
|
Crisafulli Diesel/Hydraulic Power Units |
|
| Crisafulli Electric/Hydraulic Power Units |
|
| Hydraulic Hose & Fittings |
|
WARNING - During pump operation the return hydraulic hose pressure should not exceed 100 PSI. Some control valves may cause peak over pressuring during shutdown. If the return hydraulic hose pressure may exceed 100 PSI, then consult the factory. |