Crisafulli Submersible Hydraulic PumpsTM

L-Series Severe Duty

 

.
Performance capabilities range from 840 to 3,800 GPM depending on the size selected. Total Dynamic Heads (TDH) range from 10 feet to 40 feet, depending on the pump size and hydraulic motor selected. See below for GPM and TDH for each model listed.
Description. SRS Crisafulli L Series, hydraulic powered pumps are portable, submersible pumps built for a variety of sludge & slurry applications. The Severe Duty pumps are equipped with a precision machined drive shaft, an enclosed oil filled bearing column, mechanical shaft seals, abrasion resistant, heat treated alloy pump volute & semi-open impeller (Brinell 400 hardness), heavy-duty hydraulic gear motor, and gray epoxy paint. All pumps have suction stands and threaded discharges (other discharge finishes available upon request).
Pump Size Inches
Flow - GPM
TDH - Feet
Solids Passing Inches
SRSC Part Number
Motor Part Number
Est. weight - pounds
4
840
10
2.00
HY045V-2520
HM2520
405
4
880
20
2.00
HY045V-2525
HM2525
410
4
760
30
2.00
HY045V-7620
HM7620
440
4
940
30
2.00
HY045V-7625
HM7625
445
6
1,300
20
2.25
HY065V-7620
HM7620
470
6
1,750
25
2.25
HY065V-7625
HM7625
475
6
2,150
30
2.25
HY065V-762020
HM762020
540
6
2,300
40
2.25
HY065V-762025
HM762025
550
8
3,000
20
2.50
HY085V-762020
HM762020
730
8
3,100
30
2.50
HY085V-762525
HM762525
740
10
3,800
25
3.00
HY105V-762525
HM762525
890
Standard Options
Hydraulic Slurry Gate (price is same for each size pump). “Slurry Gate” is opened to agitate and slurry the pond. Solids and liquids are drawn into the pump, blended and injected through the slurry gate into unmixed material. After a period of time, depending on material thickness, the entire pit will be slurried and the operator can close the slurry gate hydraulically from the bank. The pump will then pump the material out at high volume. No separate agitator or mixer pumps are needed. One SRS Crisafulli pump does it all. SRSC Part Number plus - SG
Crisafulli Diesel/Hydraulic Power Units
Crisafulli Electric/Hydraulic Power Units
Hydraulic Hose & Fittings